CRSC International Company Ltd.
Products
Contact Us
  • Contact Person : Mr. wang jin
  • Company Name : CRSC International Company Ltd.
  • Tel : 86-010-51846884
  • Fax : 86-010-63869194
  • Address : beijing,beijing,beijing
  • Country/Region : China

GYTA53 fiber optics

GYTA53 fiber optics
Product Detailed
Related Categories:Fiber Optic Equipment
mono-mode fiber and corrugated metal tape armour, suitable for direct burial and cable duct

Specification

1 Reference Standards

- EN 764

- IEC 60794

- IEC60332-1

- IEC60332-3

- YD/T 901-2001

2 Operating Conditions

- Altitude: ≤ 2000m. above sea level

- Temperature   : -20°C~+70°C

- Lay out temperature: above 0°C

- Maximum cable bending during installation: 20 times of cable diameter

3Optical Fibre Characteristics

No.

Description

Unit

Requirement

1

Mode field diameter at   1310nm

Mode field diameter at   1550nm

μm

9.2±0.4

10.4±0.8

2

Cladding diameter

μm

125±1

3

Cladding non circularity

%

1

4

Mode field concentricity   error

μm

≤0.8

5

Cut-off wave-length: λc

λcc

nm

1180~1330

1260

6

Attenuation at 1310nm       Max.

dB/km

≤0.35

7

Attenuation at   1550nm       Max.

dB/km

≤0.22

8

Attenuation Steps

dB

<0.1

9

Dispersion for 1287~1340nm

Dispersion for 1270~1360nm

Dispersion for 1480~1580nm

ps/km.nm

3.5

5.3

18

10

Attenuation variation at -40°C~ 80°C

3m fiber length, 50mm radius diameter

dB

<0.05

11

Color dispersion of   polarization: PMD≤ 0.2P

Ps/(km) 1/2

0.2

4Mechanical Characteristics

No.

Description

Standard

Unit

Standard Requirement

1

Tensile strain   10mm/min tensile

Tensile Force for   Short-term

                 Long-term

IEC794-1- E1

%

N

0.2

3000

1000

1.1

Increased additional attenuation  

dB

≤0.1

2

Compress test   100mm cable length

Compress strength for   Short-term

               For Long-term

IEC794-1-E3

N

3000

1000

2.1

Increased additional attenuation  

dB

≤0.1

2.2

Out sheath of Cable

Non crack

3

Repeated Bending test

Bend radius:150mm , Load 200N ,

Number   of bends 30 

IEC794-1-E6

 

3.1

Fiber and Strength member

No breakage

3.2

Out sheath of Cable

Non crack

4

Impact test

Load 10N , 5 point, 5 times/one   point

IEC794-1-E4

4.1

Increased additional attenuation  

dB

≤0.1

4.2

Out sheath of Cable

Non crack

5

Torsion test

Load 200N, 20 cycles, ±180   degrees  

IEC794-1-E7

5.1

Fiber and Strength member

No breakage

5.2

Out sheath of Cable

Non crack

6

Bending test  

Mandrill dia.600mm

Load 4000N, ,10 cycles, ±180 degrees    

IEC794-1-E11

6.1

Increased additional attenuation  

dB

≤0.1

6.2

Out sheath of Cable

Non crack

5Water Penetration Test

- Test temperature: room temperature

- Water tightness cap: L –style

- Water column: 1m

- Sample length: 3m

- Horizontal holding: 24 hours

- There shall be no any water penetrated in the end of cable.

6 Integrality of Sheath of Optical Fibre Cable

Both inner sheath and outer sheath shall withstand for one minute without breakdown the application of a test voltage 3500V r.m.50Hz.

GYTA53 fiber optics



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.