- Contact Person : Mr. wang jin
- Company Name : CRSC International Company Ltd.
- Tel : 86-010-51846884
- Fax : 86-010-63869194
- Address : beijing,beijing,beijing
- Country/Region : China
GYTA53 fiber optics
Specification
1 Reference Standards
- EN 764
- IEC 60794
- IEC60332-1
- IEC60332-3
- YD/T 901-2001
2 Operating Conditions
- Altitude: ≤ 2000m. above sea level
- Temperature : -20°C~+70°C
- Lay out temperature: above 0°C
- Maximum cable bending during installation: 20 times of cable diameter
3Optical Fibre Characteristics
No. | Description | Unit | Requirement |
1 | Mode field diameter at 1310nm Mode field diameter at 1550nm | μm | 9.2±0.4 10.4±0.8 |
2 | Cladding diameter | μm | 125±1 |
3 | Cladding non circularity | % | 1 |
4 | Mode field concentricity error | μm | ≤0.8 |
5 | Cut-off wave-length: λc λcc | nm | 1180~1330 1260 |
6 | Attenuation at 1310nm Max. | dB/km | ≤0.35 |
7 | Attenuation at 1550nm Max. | dB/km | ≤0.22 |
8 | Attenuation Steps | dB | <0.1 |
9 | Dispersion for 1287~1340nm Dispersion for 1270~1360nm Dispersion for 1480~1580nm | ps/km.nm | 3.5 5.3 18 |
10 | Attenuation variation at -40°C~ 80°C 3m fiber length, 50mm radius diameter | dB | <0.05 |
11 | Color dispersion of polarization: PMD≤ 0.2P | Ps/(km) 1/2 | 0.2 |
4Mechanical Characteristics
No. | Description | Standard | Unit | Standard Requirement |
1 | Tensile strain 10mm/min tensile Tensile Force for Short-term Long-term | IEC794-1- E1 | % N | 0.2 3000 1000 |
1.1 | Increased additional attenuation | dB | ≤0.1 | |
2 | Compress test 100mm cable length Compress strength for Short-term For Long-term | IEC794-1-E3 | N | 3000 1000 |
2.1 | Increased additional attenuation | dB | ≤0.1 | |
2.2 | Out sheath of Cable | Non crack | ||
3 | Repeated Bending test Bend radius:150mm , Load 200N , Number of bends 30 | IEC794-1-E6 |
| |
3.1 | Fiber and Strength member | No breakage | ||
3.2 | Out sheath of Cable | Non crack | ||
4 | Impact test Load 10N , 5 point, 5 times/one point | IEC794-1-E4 | ||
4.1 | Increased additional attenuation | dB | ≤0.1 | |
4.2 | Out sheath of Cable | Non crack | ||
5 | Torsion test Load 200N, 20 cycles, ±180 degrees | IEC794-1-E7 | ||
5.1 | Fiber and Strength member | No breakage | ||
5.2 | Out sheath of Cable | Non crack | ||
6 | Bending test Mandrill dia.600mm Load 4000N, ,10 cycles, ±180 degrees | IEC794-1-E11 | ||
6.1 | Increased additional attenuation | dB | ≤0.1 | |
6.2 | Out sheath of Cable | Non crack |
5Water Penetration Test
- Test temperature: room temperature
- Water tightness cap: L –style
- Water column: 1m
- Sample length: 3m
- Horizontal holding: 24 hours
- There shall be no any water penetrated in the end of cable.
6 Integrality of Sheath of Optical Fibre Cable
Both inner sheath and outer sheath shall withstand for one minute without breakdown the application of a test voltage 3500V r.m.50Hz.
GYTA53 fiber optics